Faire un don

Des accidents nucléaires partout

Etats-Unis : River Bend : Sûreté dégradée suite à l’absence d’analyse d’une configuration du dissipateur ultime de chaleur




30 juillet 2014


Des mesures compensatoires ont été mises en œuvre afin de restaurer la conformité aux exigences prévues lors de la conception... il y a 29 ans.

Type : BWR-MARK 3 - Puissance : 3091 MWth - Première divergence : 10/1985

Available in english only.


Event Number : 50324

Facility : RIVER BEND - 4 State : LA -

Unit : [1] RX Type : [1] GE-6

Event Date : 07/30/2014 - Event Time : 09:40

Emergency Class : NON EMERGENCY 10 CFR Section : 50.72(b)(3)(ii)(B) - UNANALYZED CONDITION

Initial PWR : 100% - Current PWR : 100%

Event Text

ULTIMATE HEAT SINK IN AN UNANALYZED CONDITION

"On July 30, 2014, at [0940 CDT], with the plant operating at 100% power, a review of an engineering analysis of the ultimate heat sink (UHS) determined that the UHS had been in an unanalyzed condition that degraded plant safety. This condition was the result of a design basis deficiency for the UHS that did not account for the adverse effects of system leakage on compliance with the 30-day inventory required by Regulatory Guide 1.27. The system design basis requires that 30-day inventory be maintained, with the assumption that no replenishment of the UHS occurs for the entire duration of the postulated event.

"In support of the development of the engineering analysis, compensatory measures have been implemented which provide adequate assurance that the UHS will perform its design safety function. Corrective actions to restore full compliance with design basis requirements are in development.

"This event is being reported in accordance with 10 CFR 50.72 (b)(3)(ii) as an unanalyzed condition that degraded the safety function of the UHS."

https://www.sortirdunucleaire.org/ecrire/?exec=articles_edit&id_rubrique=378&new=oui


La surveillance des installations nucléaires au quotidien ? C’est grâce à vos dons que nous pouvons la mener !
Pour surveiller au jour le jour les incidents dans les installations nucléaires, les décrypter et dénoncer les risques permanents qui sont trop souvent minimisés - voire cachés par les exploitants, nous mobilisons tout au long de l’année des moyens humains et techniques.
Pour continuer ce travail de lanceur d’alerte et donner, au plus proche de leur survenue, des informations sur les inquiétants dysfonctionnements d’un parc nucléaire vieillissant, nous avons besoin de votre soutien financier !

Faire un don