1er août 2014
La société Crane nucléaire, qui n’aurait livré des vannes non conformes que pour des réacteurs en projet AP 1000, a mis un numéro d’appel pour répondre aux questions.
Available in english only.
Event Number : 50336
Rep Org : CRANE NUCLEAR, INC.
City : BOLINGBROOK State : IL
Event Date : 08/01/2014 - Event Time :
Emergency Class : NON EMERGENCY 10 CFR Section : 21.21(d)(3)(i) - DEFECTS AND NONCOMPLIANCE
Event Text
PART 21 REPORT - SAFETY-RELATED VALVES ASSEMBLED WITH NON-SAFETY RELATED LEVERS
Crane did not provide safety related levers, for manual type safety valves, on a recent shipment. Crane was advised by their customer that valves provided for AP1000 PV10 Scopes (VDS 101 and VDS 150) should have had safety-related levers.
Crane believes the only affected valves are those that have been provided on the AP 1000 project.
If you have questions please contact ; Rosalie Nava, Director Safety and Quality Phone 630-226-4940 Fax 630-226-4646 Email RNAVA@cranevs.com
https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2014/20140804en.html